EF-202/204
DUAL/FOUR CHANNEL MASTER STATION
E-200 SERIES CABLE INTERCOM SYSTEM
OWNERS MANUAL
PRELIMINARY ISSUE 16/04/2012
AUDIO ELECTRONICS DESIGN
EQUIPOS EUROPEOS ELECTRÓNICOS, S.A.L
Avda. de la Industria, 50. 28760 TRES CANTOS-MADRID (SPAIN).
34-91-761 65 80 34-91-804 43 58 [email protected]
www.altairaudio.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 33 34

Shrnutí obsahu

Strany 1 - EF-202/204

EF-202/204DUAL/FOUR CHANNEL MASTER STATION E-200 SERIES CABLE INTERCOM SYSTEMOWNERS MANUAL PRELIMINARY ISSUE 16/04/2012

Strany 2

102) Using single conductor shielded cable:BALANCED INPUT:PA OUTPUT CONNECTIONThe PA and SA output signal is carried out through a XLR-3-32 male conne

Strany 3 - -THIS OWNERS MANUAL

11The output connection depends on two factors, the first is the type of input signal balanced or unbalanced, and the second the ground configuration

Strany 4 - 1. INTRODUCTION

12BALANCED OUTPUT:RELAY CONNECTION Base unit allows the control of an internal general relay allowing control over an external device or application

Strany 5

13EXTERNAL SPEAKER CONNECTION In the master station rear panel is available a connector to plug an external speaker , which allows us to monitor the

Strany 6 - REAR PANEL

14The next picture shows the habitual connection of an intercom system comprised by eight beltpack units (two per channel) and a EF-204 base station.

Strany 7 - 4. INSTALLATION

15Schematic diagram:System operation is strait forward. You can connect your headset , to any of the bases. Microphone signal from the preamp out

Strany 8

16 SWITCHES TO GROUND OPEN COLLECTORThe general purpose inputs can control all the buttons on the base stati

Strany 9 - PROGRAM INPUT

17INTERCOM LINE CONNECTIONS – 4W MODEThe base station includes 2x (EF-202) / 4x (EF-204) intercom lines. Each line comprises two connectors for gender

Strany 10

18among all intercom channels. Each channel provides a CALL switch , a MIC on/off switch (TALK) , a LISTEN on/off switch , and a listen level contr

Strany 11

19NOTE: Headsets are of the double or single muff type. In case of using a double muff headset, the two speakers should be wired in parallel.HEADSET S

Strany 12

21. INTRODUCTION...

Strany 13 - GND SLEEVE

20The remote mic kill switch carries out the function upon pressing it. This means that the units (wired and wireless beltpacks, desk stations units,

Strany 14

21The TALK switches have two operation modes. When this switch is pressed quickly, the microphone changes its state; if it was enabled, being presse

Strany 15

22MEMORIES The unit has four memories (PRESETS) that allow us to record and retrieve the position of all the switches, so we can return to previousl

Strany 16

23USBPC connection (USB) is made via an USB A MALE / B MALE, allowing you to control all functions of the base stations ALTAIR EF-202 and EF-204. Th

Strany 17 - 5. OPERATION

24Each intercom line has its own intercom line terminal impedance switch placed at the rear panel of the unit.By default, all the switches must be i

Strany 18

256. INTERNAL CONFIGURATION SETTINGSSETTING THE PROGRAM INPUT SEND AND THE PROGRAM INTERRUPTThe program input send, and the program interruption (prog

Strany 19

26INTERNAL CONFIGURATION SETTING. This chart is over the top cover. Remove the unit partially from the rack to read it.EF-202/EF-204 MASTER STATION -

Strany 20

27The internal parameters of the base station can be configured as follows:  Hold down the speaker switch , for five seconds. At that time the unit

Strany 21

28LOCAL BUZZER ACTIVATION BY:SWITCH → BUZZER KILL .LED BLINKING → BUZZER always active.LED OFF → The BUZZER is turned off when the local BUZZERK

Strany 22

29PARTY LINE A TO PA/SA OUTSWITCH → CALL B.LED BLINKING → The party line A is sent to the PA output .LED OFF → The party line A is not sent to the P

Strany 23

3HEADSET MICROPHONE TYPE (PHANTOM) .

Strany 24

30RELAY ACTIVE BY PA OUT KEYSWITCH → PRESET 1.LED BLINKING → The relay is activated when the PA output is active with the PA out switch. Factor

Strany 25

317. BLOCK DIAGRAMEF-202/EF-204 MASTER STATION - SERIE E-200

Strany 26

328. TECHNICAL SPECIFICATIONSINTERCOM LINEIMPEDANCE:• 220 Ω AC.• 4700 Ω DC.NOMINAL/MAXIMUM LEVEL:• -10 dBu / +3 dBu.FREQUENCY RESPONSE:• 100 Hz – 10

Strany 27

339. WARRANTYThis unit is warranted by Equipos Europeos Electrónicos to the original user, against flaws in the manufacturing and in the materials, f

Strany 28

34European UnionWaste Electronics InformationUnión EuropeaInformación sobre residuos electrónicosWaste from Electrical and Electronic Equipment (WEEE)

Strany 29

41. INTRODUCTIONCongratulations on your purchase of the ALTAIR master station EF-202/EF-204 of the E-200 series intercom system. There is a lot

Strany 30

52. SWITCHES, CONTROLS, ADJUSTMENTS AND CONNECTORSThese are the switches, controls, adjustments and connectors that you can find in your ALTAIR interc

Strany 31 - 7. BLOCK DIAGRAM

6REAR PANEL EF-202/EF-204 MASTER STATION - SERIE E-200

Strany 32 - 8. TECHNICAL SPECIFICATIONS

73. WORKING PRECAUTIONSThe manufacturer is not responsible of any damage that can possibly happen to the intercom master station outside the limits of

Strany 33 - 9. WARRANTY

8 Make sure that the unit is disconnected from the mains. In the unit rear panel are placed the mains connector and the fuse holder . The box bello

Strany 34 - Unión Europea

9The input connection depends on two factors, the first is the type of input signal balanced or unbalanced, and the second the ground configuration of